Sensoray 2518 User Manual
Page 14
Sensoray Model 2518/2519 Ethernet Smart A/D™
11
Configuration
The following table shows the mapping between
channels and affiliated shunt pairs for SCC enables.
Example:
To enable the SCC for sensor channel 2, install shunts
E11 and E19 on the lower Smart A/D™ board.
Example:
To disable the SCC for sensor channel 14, remove
shunts E15 and E23 on the upper Smart A/D™ board.
4.3.7 Default SCC Configuration
Models 2518 and 2519 are factory programmed so that
the SCCs for all sensor channels are disabled. Shunts E9
through E24 are all removed as shipped from Sensoray.
Table 4: Signal Conditioner shunt mapping
Channel
5
1
8
B
o
a
r
d
Lower
0
1
2
3
4
5
6
7
Upper
8
9
10
11
12
13
14
15
Shunt
Numbers
E9
E10
E11
E12
E13
E14
E15 E16
E17
E18
E19 E20
E21
E22
E23 E24
This manual is related to the following products: