For the installer – Scotsman RS100 User Manual
Page 5

FOR THE INSTALLER
1. If installing a carbonator, locate it nearby.
2. Route the drain lines to the building drain. Vent
the drain tubes if installing at the back of the
cabinet.
3. Locate electrical supply (for cord - 115v outlet).
The outlet must be properly grounded. The circuit
must be fused and no other electrical appliance
should be on the circuit.
ALL ELECTRICAL WIRING MUST CONFORM
TO NATIONAL AND LOCAL CODES
4. Remove any shipping materials.
Refer to the plumbing schematic on the back of
the cabinet (all stub lines are labeled) and:
A. Connect three (for 6 Valve Units) or two (for
8 valve units) carbonated water supply lines
(field supplied) from the remote carbonator to
the carbonated water stub line at the dispenser
cold plate.
B. Connect water supply line (field supplied)
from building source to carbonator (filtered water
is recommended).
C. Connect a water supply line to the plain water
stub line on the cold plate for use with the
non-carbonated valve.
NOTE: If ALL valves need
carbonation, connect an additional
carbonated water line from the
carbonator to the plain water stub line
on the cold plate.
D. Connect syrup lines to the cold
plate syrup stub lines.
6. Connect primary CO
2
regulator to
CO
2
tank. Secure secondary regulators
to wall or other stationary surface.
7. Connect CO
2
line between outlet of
primary regulator and inlet of
secondary regulators.
8. Connect CO
2
lines between outlets
of secondary regulators and syrup
tanks. Or to syrup pumps in the case of
Bag-In-Box.
DRAIN TUBES
INSTALLING DRAIN AND SODA LINES
BEVERAGE
TUBING
RS100 and RS150
October 1993
Page 5