Cleaning and sanitizing – Scotsman RS100 User Manual
Page 14

Monthly/Initial Start Up:
Sanitize the Ice Storage System.
Note: this should only be done by qualified
personnel.
1. Unplug the Refreshment Stand’s electrical cord
from the electrical power.
2. Remove cover and
discard all remaining ice
3. Mix a solution of 1
ounce of household
bleach to 2 gallons of
potable water, or: mix a
solution of any approved
sanitizer, following the
directions for mixing
and applying that
sanitizer.
4. Unscrew the sweep
arm from rotor shaft,
and pull the rotor from
hopper.
5. Using a clean cloth or sponge, wipe all interior
surfaces of the ice storage hopper with the
sanitizing solution, allow to air dry.
6. Wipe all surfaces of the rotor with the sanitizing
solution, and allow to air dry.
7. Pull out and remove the upper front panel.
A. Twist the clear ice chute 1/3 turn, and pull down
to remove.
B. Locate the two thumb screws holding the lower
brace: remove them and the brace.
C. Locate the three thumb screws holding the
upper ice chute; remove them (1 on top and 2
below). Remove the upper ice chute from the
machine.
Thoroughly wipe the surfaces of the bin door and
both ice chutes with the sanitizing solution, and
allow to air dry.
Place the lower brace back onto the unit, and
secure with the two thumb screws.
Place the upper ice chute back onto the dispenser,
secure with the three thumb screws.
Place the clear ice chute back onto dispenser.
Place the upper front panel back onto the machine.
8. Wipe the inside surface of the cover with the
sanitizing solution, and allow to air dry.
9. Reassemble the rotor and hopper, re-wipe the
surfaces of the rotor and allow to air
dry.
10. Wipe the top edge of the ice
hopper with the sanitizing solution,
allow to air dry.
11. Pour in fresh, sanitary ice and
replace the cover. Plug the unit in, it
is now ready to dispense ice
Note: the cold plate is not in contact
with the ice that is dispensed.
DRAIN HOSE
LOWER
BRACE
CLEANING AND SANITIZING
Ice hopper contains parts
that can move at any
time and will cause injury
if hands are in the way.
Do
not remove cover
until the unit has been
unplugged from the
electrical power.
CLEAR ICE
CHUTE
POUR HOT WATER
DOWN SINK
UPPER ICE
CHUTE
SNAP-OFF FRONT
PANEL
LIGHT
BULB
SWEEP
ARM
ROTOR
RS100 and RS150
October 1993
Page 14