Repair, Moving, Removal & replacement – Scotsman RS100 User Manual
Page 19

MOVING
1. Sanitize syrup system as instructed on page 15.
2. Shut off water supply.
3. Unplug carbonator.
4. Remove connectors from syrup tanks.
5. Connect an empty syrup tank to one circuit.
6. Actuate valve on that circuit until only CO
2
(gas)
flows from it.
7. Repeat steps 5-6 for all valves.
8. Remove all ice
9. Drain all water from bin and drain circuit.
10. Remove all field connections from cold plate.
REMOVAL & REPLACEMENT
To Replace Vend Switch:
1. Disconnect Electrical Power.
2. Pull out and remove upper front panel.
Lever Type Actuation:
A. Twist ice chute 1/3 turn and pull down to
remove.
B. Remove screws holding valve mounting plate to
cabinet. Pull valve and plate assembly out and
away from cabinet. Switch is mounted to valve
plate.
Reverse steps to reassemble.
Push Button Actuation:
Locate vend switch behind push button assembly
of upper front panel.
3. Remove wires from switch.
4. Remove screw and nut retaining switch to
mounting plate, and remove switch from dispenser.
5. Reverse steps to reassemble.
To Replace Gear Motor Assembly:
1. Disconnect electrical power.
2. Remove cover from hopper.
3. Unscrew sweep arm holding rotor to gearmotor
shaft.
4. Remove rotor from gearmotor shaft.
5. Remove splash panel
6. Twist ice chute 1/3 turn and pull down to remove.
7. Remove ice chute mounting plate.
8. Remove screws holding valve mounting plate to
cabinet. Pull valve assembly out and away from
cabinet.
9. Mark location of gearmotor bracket on cabinet.
10. Disconnect gearmotor electrical leads in
control box
11. Remove (4) screws holding gearmotor to
bracket.
12. Remove (4) screws holding gearmotor bracket
to cabinet.
13. Swing gearmotor bracket out of cabinet.
14. Pull gearmotor from cabinet.
15. Reverse to reassemble. Gearmotor bracket
should be installed where it was, so that the rotor
should clear bin surface by 1/8" to 1/4". If needed,
the slots on the gearmotor bracket will allow the
position of the rotor to be adjusted.
If the dispenser is going
to be moved to another
building, shipped any distance, or if there is any
possibility that it may be exposed to freezing
temperatures, it must be thoroughly cleared of all
liquids to prevent damage.
Electrical Shock
Hazard.
Unplug unit before
servicing.
RS100 and RS150
October 1993
Page 19