FOR THE PLUMBER

CONFORM TO ALL APPLICABLE CODES

Water Inlet

Air Cooled Models: The recommended water

supply is clean, cold water. Use 3/8" O.D. copper

tubing, connect to the 3/8" male flare at the back of

the cabinet. Install a hand valve near the machine

to control the water supply.
Water Treatment: In most areas, a water filter of

some type will be useful. In areas where the water

is highly concentrated with minerals the water

should be tested by a water treatment specialist,

and the recommendations of the specialist

regarding filtration and/or treatment should be

followed.
Water Cooled Models: A separate 3/8" O.D.

copper line is recommended, with a separate hand

valve to control it. It is connected to a 3/8" FPT

condenser inlet at the back of the cabinet. The

water pressure to all lines must always be above

20 psig, and below 80 psig.

Drains

Air Cooled Models: There is one 3/4" FPT drain

at the back of the cabinet, the drain line is of the

gravity type, and 1/4 inch per foot fall is an

acceptable pitch for the drain tubing. There should

be a vent at the highest point of the drain line, and

the ideal drain receptacle would be a trapped and

vented floor drain. Use only 3/4" rigid tubing.
Water Cooled Models: In addition to the above

mentioned drain, a separate condenser drain must

be installed. Connect it to the 1/2" condenser drain

connection at the back of the cabinet.

MDT5N25 & MDT5N40

May 2001

Page 6

WATER INLET

CABINET

DRAIN

OPTIONAL

WATER

FILTER

WATER INLET

SHUT OFF

VALVE

VENTED

DRAIN TUBE

FLOOR DRAIN

WATER COOLED DETAIL