beautypg.com

Refrigeration service – Scotsman MDT5N25 User Manual

Page 32

background image

MDT5N25 & MDT5N40

May 2001

Page 31

REFRIGERATION SERVICE

General Information:
Work on the refrigeration system should only be

done when it is certain that the system needs

repair.

·

Refrain from checking refrigeration

pressures without reason. Visual inspection

of the water system, observation of the ice

formation, amp draw, voltage, and other

techniques will lead to proper diagnosis.

Scotsman also recommends that, at the time of

initial start up, gauges not be used.

·

If gauges must be used, don’t always check the

high side pressure. If the condenser is clean and

seems to be operating correctly, it most likely is.

The low side pressure is more important on an

ice machine than the high side.

·

If gauges must be used, use very short hoses to

minimize refrigerant discharged into the air.

·

Refrigerant should not be added except as a

way to determine the proper operation of the

product. If the system was low on refrigerant,

there is a leak, and it must be found and

repaired.

·

This system has a critical charge, it must be

recharged with the correct amount of refrigerant

as listed on the nameplate of the ice machine, or

performance will suffer.

·

Anytime the refrigeration system has been

opened, the dryer should be replaced. Note:

Only a HFC type dryer should be used.

·

When brazing the tubing connections to

components such as the TXV, the component

must be protected by heat sink material.

Recover, reclaim or recycle refrigerant. The

method chosen is up to the service company. Any

refrigerant placed into a Scotsman ice machine

must meet ARI spec 700-88. Reclaim programs are

available through most refrigerant wholesalers.
Access Valves: To use the access valves:
Remove the cap from the stem, use a 3/16" allen

wrench to check that the valve is CLOSED. The

remove the core cap.
Close the valve and replace the caps when the

job is finished. The valve must be closed and

the caps must be on or the valve will leak.

Torque Stem Cap to

8-12 ft. lb.

Torque Stem to

6-8 ft. lb.

Torque Core

Cap to 7-12

ft. lb.

Access Valves

Note: There are no valve

cores in this valve.

Allen

Wrench