MAINTENANCE AND CLEANING

1. Air Cooled Models: Check the air cooled

condenser for lint, dirt or grease build-up. Clean

with vacuum or soft brush until light can be seen

thru the fins.

2. The ice machine senses water level by a probe

located in the water reservoir. At least twice a year,

the probe should be removed from the reservoir,

and the tip wiped clean of mineral build-up.
3. The bin control uses devices that sense light,

therefore they must be kept clean enough so that

they can “see”. At least twice a year, remove the

bin control sensors from the grommets in the ice

chute, and wipe them clean.
4. The bearing in the breaker should also be

checked at least two times per year.
A. Check the bearing by:

·

removing the ice chute cover

·

unscrewing the ice sweep

·

removing the water shed

·

unscrewing the breaker cover.

·

unscrewing the auger stud

Inspect the assembly, looking for wear.

See Removal and Replacement to replace bearing

or seals. Reverse to reassemble.

5. Check and tighten all bolts and screws.