beautypg.com

Scotsman MDT5N25 User Manual

Page 31

background image

REFRIGERATION SERVICE: R-404A (HP62)

THIS ICE MACHINE USES HP62 REFRIGERANT

AND POLYOLESTER COMPRESSOR OIL.
DO NOT USE MINERAL OIL IN THIS

REFRIGERATION SYSTEM.

·

R-404A is a “Near Azeotrope”, and therefore

liquid charging is required.

Weigh into the discharge side as much as

possible of the charge as liquid refrigerant.
Install a sight glass between the manifold

and the suction side hose. Carefully meter

liquid refrigerant into the suction side, using

the manifold valve to “flash off” the liquid

before it enters the ice machine. Do this until

the proper charge has been weighed into the

system.

·

When the system is serviced, a special liquid

line dryer is required.

·

Polyolester oil absorbs water very easily, and

therefore when the system is opened for

service, it must be re-sealed as soon as

possible (15 minutes maximum).

·

Special leak detection equipment is required to

locate small refrigerant leaks. Usually a leak

detector capable of detecting a Halogenated

refrigerant or HFC-134A will work. Check with

the leak detector manufacturer if in doubt.

·

As with any other refrigerant, do NOT mix HP62

with pressurized air when leak testing.

MDT5N25 & MDT5N40

May 2001

Page 30

VAPOR VAPOR

TEMP.

PRESSURE TEMP. PRESSURE

(DEG F)

(PSIG)

(DEG F)

(PSIG)

-20 . . . . 17

70 . . . . . . 146

-18 . . . . 18

72 . . . . . . 150

-16 . . . . 20

74 . . . . . . 155

-14 . . . . 21

76 . . . . . . 161

-12 . . . . 23

78 . . . . . . 166

-10 . . . . 24

80 . . . . . . 171

-8 . . . . 26

82 . . . . . . 177

-6 . . . . 28

84 . . . . . . 182

-4 . . . . 29

86 . . . . . . 188

-2 . . . . 31

88 . . . . . . 194

0 . . . . 33

90 . . . . . . 200

2 . . . . 35

92 . . . . . . 206

4 . . . . 37

94 . . . . . . 212

6 . . . . 39

96 . . . . . . 219

8 . . . . 41

98 . . . . . . 225

10 . . . . 43

100 . . . . . 232

12 . . . . 46

102 . . . . . 239

14 . . . . 48

104 . . . . . 246

16 . . . . 50

106 . . . . . 253

18 . . . . 53

108 . . . . . 260

20 . . . . 55

110 . . . . . 268

22 . . . . 58

112 . . . . . 275

24 . . . . 60

114 . . . . . 283

26 . . . . 63

116 . . . . . 291

28 . . . . 66

118 . . . . . 299

30 . . . . 69

120 . . . . . 307

32 . . . . 72

122 . . . . . 316

34 . . . . 75

124 . . . . . 324

36 . . . . 78

126 . . . . . 333

38 . . . . 81

128 . . . . . 342

40 . . . . 85

130 . . . . . 351

42 . . . . 88

132 . . . . . 360

44 . . . . 91

134 . . . . . 370

46 . . . . 95

136 . . . . . 379

48 . . . . 99

138 . . . . . 389

50 . . . . 102

140 . . . . . 399

52 . . . . 106

142 . . . . . 409

54 . . . . 110

144 . . . . . 420

56 . . . . 114

146 . . . . . 430

58 . . . . 118

148 . . . . . 441

60 . . . . 123

150 . . . . . 452

62 . . . . 127

152 . . . . . 464

64 . . . . 132

154 . . . . . 475

66 . . . . 136

156 . . . . . 487

68 . . . . 141

158 . . . . . 499

Pressure-Temperature Chart for HP62