MAINTENANCE AND CLEANING

In some areas, the water supply to the ice maker

will contain a high concentration of minerals, and

that will result in an evaporator and auger

becoming coated with these minerals, requiring a

more frequent removal than twice per year. If in

doubt about the condition of the evaporator and

auger, the auger can be removed so the parts can

be inspected.

Note: Water filters can filter out suspended solids,

but not dissolved solids. “Soft” water may not be

the complete answer. Check with a water treatment

specialist regarding water treatment.
For more information on removal of these

parts, see REMOVAL AND REPLACEMENT.
1. To remove the auger, remove the front and top

panels.
2. Push bail clamp off of cover and remove cover.
3. Unscrew and remove ice sweep.
4. Remove ice chute from evaporator.
5. Remove 4 allen screws holding breaker to

evaporator.
6. Pull up to remove auger.
After the auger has been removed, allow the auger

to dry: if the auger is not bright and shiny, it must

be cleaned.
Clean the auger and evaporator as required. DO

NOT HONE THE EVAPORATOR.
7. Replace the water seal.
8. Reverse to reassemble.