FOR THE INSTALLER: Remote Condenser

Scotsman Condenser:

Locate the condenser as near as possible to the
interior location of the ice maker.

Location of the condenser is limited by the
specific length of pre-charged refrigerant tubing
supplied for the application. The pre-charged
tubing connects the icemaker to the remote
condenser. The condenser must be above the ice
maker.

Select the best available location, protecting the
condenser from extremes of dirt, dust, and sun.

Meet all applicable building codes.

Roof Attachment:

Install and attach the remote condenser unit to
the roof of the building, using the methods and
practices of construction that conform to the local
building codes, including having a roofing
contractor secure the condenser to the roof.