beautypg.com

Mcm1062r, Removal and replacement – Scotsman MCM1062R User Manual

Page 27

background image

REMOVAL AND REPLACEMENT

/////////////////////////////////WARNING//////////////////////////////

Disconnect electrical power before beginning.

/////////////////////////////////////////////////////////////////////////////////

Water Distributor Tubes And Manifold Tubes

To remove the water distributor tube and manifold
tube:

1. Pull out to unsnap catches and remove the front
panel.

2. Remove the evaporator cover.

3. Slide the water distributor tube to the front about
1/8-inch along the top of the evaporator plate, until
the water distributor tube can be unsnapped from
the flexible notch and lifted upward to the right
side.

4. Unsnap and disconnect water distributor tubes
from the water manifold section. To replace the
water distributor tubes and manifold tubes, reverse
the removal procedure. BE SURE the notches in
the water manifold tubes properly engage the
alignment keys in the tee. BE SURE the water
distributor tube is securely fastened
at the notch at both sides of the
evaporator plate. Check identical
attachment for the left water
distributor tube and notch; also, that
the distributor/manifold connections
at the top center of each evaporator
plate is snug against the top of the
plate.

Cube Size Control

To remove the cube size control:

1. Remove front panel.

2. Remove cover from control box.

3. Trace capillary tube, from the cube size control
to the refrigerant suction line.

4. Remove the coiled capillary tube bulb from the
tube well on the suction line.

5. Remove electrical leads from the cube size
control.

6. Remove screws and the cube size control. To
replace the cube size control, reverse the removal
procedure. Be certain that the bulb is re-insulated.

WATER

DISTRIBUTOR

TUBES

INLET WATER

VALVE

CUBE SIZE

CONTROL

MCM1062R

October 1993

Page 27