background image

TRANSDUCER

LOCATION

TRANSDUCER

REMOVAL OF TRANSDUCER

PLUG

CONNECTION

TRANSDUCER

SOCKET

REMOVAL AND REPLACEMENT

TRANSDUCER

1. Disconnect electrical power BEFORE removing
transducer.

2. Open bin door and locate the transducer socket.

3. Twist inner portion of transducer counter-
clockwise and push up gently.

4. Pull transponder down until plug connection is
accessible.

5. Unplug transducer and remove from the
machine.

6. Reverse steps 1-5 to reassemble.