Symptom

Possible Cause

Probable Correction

No ice, not operating

No power at wall outlet

Check circuit breaker/fuses

No power at auxiliary drain

pump power outlet

Check for kinked drain hose,
blocked screen or blocked vent
outlet or hose.

Disconnected selector switch

Reconnect and check for proper
operation.

Room temperature below 55

o

F.

(13

o

C)

Bin thermistor has unit shut off

Ice touching bin thermistor

Normal operation

No ice.

Will not make ice. Water

reservoir is empty. Evaporator is
cold with thin or no ice slab

.

Water supply turned off

Turn on water supply

Loose or missing reservoir cap

Tighten or replace

Water slide return tube out of
reservoir

Reposition tube

Inlet tube out of position and
missing reservoir

Reposition tube

Water inlet tube frozen near
evaporator

Thaw and reposition tube

Defective inlet water valve

Test and repair or replace

An ice slab only partially
released from evaporator and
water was bridged down into the
bin

Look for interference with cutter
grid and clean the evaporator
plate

Will not make ice. Water
reservoir is empty. Evaporator is

cold with 3/4" thick or larger ice
slab

Slab will not release during
harvest due to scale build up

Clean the evaporator plate

Defective or disconnected hot
gas valve

Test and repair or replace

Room temperature over 100

o

F

(38

o

C)

Move machine or reduce heat

Off LED on.

Open or disconnected bin or
evaporator thermistor or
thermistor wiring

Test thermistor & wiring harness