Flow Chart - Overall Operation

July 2007

Page 15

CS0415

Service Manual

Switch On

Flush Mode

Begins

Freeze Mode

Begins

Harvest Mode

Begins, water

drains and refills

Water Level

Drops Below

Sensor?

25 min. of

freeze time?

Yes

No

Yes

Compressor and

Hot Gas Valve on

for 1 minute

Bin Full?

Yes

Compressor and

Hot Gas Valve on

for 1 minute

No

Evaporator

more than

52

o

F.?

Compressor and

Hot Gas Valve on

for 3 minutes.

No

Freeze Mode

Idle Mode

Yes

Evaporator

more than

52

o

F.?

Yes

Evaporator

more than

52

o

F.?

No

Yes

Yes

Evap

Thermistor

Unplugged?

No

Yes

Yes

No

Continued Harvest

Mode

Evaporator

more than

52

o

F.?

16 minutes

max harvest

time?

No

Failure Mode

Yes

Bin Full?

Yes

Yes

No

No