beautypg.com

Operational characteristics: cme1656r – Scotsman CME1356R User Manual

Page 37

background image

Operational Characteristics: CME1656R

Cycle Times (minutes):

System Pressures (PSIG):

Number of Evaporators:

·

6

Refrigerant Charge

·

288 ounces of R-404A

Typical Compressor Amps,
single phase

·

freeze 15 - 16

·

harvest 22 - 23

Typical Compressor Amps,
three phase

·

freeze 9 - 10

·

harvest 13 - 14

Typical Harvest Ice Weight

·

19.2 lb.

Superheat

·

The TXV will control a nominal superheat point
that can vary unit to unit from 11oF. to 17oF.
While controlling that point the superheat can
also range + or - 4oF. without affecting
performance.

Hi Pressure Control - Automatic Reset

·

Hi Pressure Cut Out - 450 PSIG

·

Hi Pressure Cut In - 350 PSIG

Headmaster Valve

·

Setting is 240 PSIG

CME1356R and CME1656R

March 2003

Page 37

70

o

F. condenser air 70

o

F. indoor

air, 50

o

F. water

90

o

F. condenser air 90

o

F. indoor

air, 70

o

F. water

Freeze

15 ½ - 17 ½

18 - 19

Harvest

2 ½

2 ½

70

o

F. condenser air 70

o

F. indoor

air, 55

o

F. water

90

o

F. condenser air 90

o

F. indoor

air, 70

o

F. water

Suction: End of Freeze

30 - 32

33 - 35

Suction: Peak in Harvest

75 - 85

90 - 100

Discharge: 5 minutes into Freeze 230 - 250

275 - 295

Discharge: Minimum in Harvest

100

110

This manual is related to the following products: