beautypg.com

Operational characteristics: cme1356r – Scotsman CME1356R User Manual

Page 36

background image

Operational Characteristics: CME1356R

Cycle Times (Minutes):

System Pressures (PSIG)

Number of Evaporators:

·

5

Refrigerant Charge

·

288 ounces of R-404A

Typical Compressor Amps,
single phase

·

freeze 14 - 15

·

harvest 17 - 18

Typical Compressor Amps,
three phase

·

freeze 8 - 9

·

harvest 10 - 11

Typical Harvest Ice Weight

·

16.0 lb

Superheat

·

The TXV will control a nominal superheat point
that can vary unit to unit from 11oF. to 17oF.
While controlling that point the superheat can
also range + or - 4oF. without affecting
performance.

Hi Pressure Control - Automatic Reset

·

Hi Pressure Cut Out - 450 PSIG

·

Hi Pressure Cut In - 350 PSIG

Headmaster Valve

·

Setting is 240 PSIG

CME1356R and CME1656R

March 2003

Page 36

0

o

F. condenser air 70

o

F. indoor

air, 55

o

F. water

90

o

F. condenser air 90

o

F. indoor

air, 70

o

F. water

Freeze

11 ½ - 12 ½

16 - 17

Harvest

3

2 ½

70

o

F. condenser air 70

o

F. indoor

air, 55

o

F. water

90

o

F. condenser air 90

o

F. indoor

air, 70

o

F. water

Suction: End of Freeze

29 - 31

30 - 32

Suction: Peak in Harvest

70 - 80

95 - 105

Discharge: 5 minutes into Freeze 230 - 250

275 - 285

Discharge: Minimum in Harvest

80

100

This manual is related to the following products: