Troubleshooting 11, Scv32, Troubleshooting – Scotsman SCV32 User Manual
Page 12
Troubleshooting
SCV32
February 2003
Page 11
Symptom
Possible Cause
Probable Fix
Cabinet too warm
Switched off
Check temperature control
Cabinet wrong temperature
Temperature control out of
adjustment
Check adjustment
Temperature control failure
Call for service
Operates too long
Dirty condenser fins
Clean condenser fins
Cabinet full of warm product
Unit must operate for many hours to
cool warm product
Door gasket not tight
Check gasket fit
Thick frost on evaporator
Shut unit off until frost melts off, check
thick frost symptom below
Unit in very warm conditions
Sunlight or high room temperatures
will increase operating time
Makes excessive noise
Fan will make noise
May be normal
Fan blade contacting shroud
Check for free fan blade rotation
Will not cool
Dirty condenser fins
Clean condenser fins
Fan motor not turning blade
Check fan motor/call for service
Low on refrigerant
Check system/call for service
Compressor not operating
Check compressor/call for service
Thick frost on evaporator
Gasket not sealing
Check gasket
Door not closing
Check door
Thermostat not keeping unit off long
enough
Check thermostat. Should cut in at
44
o
F evaporator temp. Cut out varies.
Excessive operating time
Check for cause (see above)
Cabinet light does not work properly
Light burned out
Replace bulb
Door switch does not close
Check/replace door switch
Cannot switch light on with door
closed
Check/replace rocker switch
Water running from inside cabinet
Drain trough hose plugged
Clean hose
Water leak
Drain hose out of position
Call for service
Drain pan overfilling
Check door and door gasket