Troubleshooting

SCV32

February 2003

Page 11

Symptom

Possible Cause

Probable Fix

Cabinet too warm

Switched off

Check temperature control

Cabinet wrong temperature

Temperature control out of
adjustment

Check adjustment

Temperature control failure

Call for service

Operates too long

Dirty condenser fins

Clean condenser fins

Cabinet full of warm product

Unit must operate for many hours to
cool warm product

Door gasket not tight

Check gasket fit

Thick frost on evaporator

Shut unit off until frost melts off, check
thick frost symptom below

Unit in very warm conditions

Sunlight or high room temperatures
will increase operating time

Makes excessive noise

Fan will make noise

May be normal

Fan blade contacting shroud

Check for free fan blade rotation

Will not cool

Dirty condenser fins

Clean condenser fins

Fan motor not turning blade

Check fan motor/call for service

Low on refrigerant

Check system/call for service

Compressor not operating

Check compressor/call for service

Thick frost on evaporator

Gasket not sealing

Check gasket

Door not closing

Check door

Thermostat not keeping unit off long
enough

Check thermostat. Should cut in at
44

o

F evaporator temp. Cut out varies.

Excessive operating time

Check for cause (see above)

Cabinet light does not work properly

Light burned out

Replace bulb

Door switch does not close

Check/replace door switch

Cannot switch light on with door
closed

Check/replace rocker switch

Water running from inside cabinet

Drain trough hose plugged

Clean hose

Water leak

Drain hose out of position

Call for service

Drain pan overfilling

Check door and door gasket