beautypg.com

Adjustments – Scotsman C1448R User Manual

Page 18

background image

C1448, C1848, C2148

Remote Condenser Models - User Manual

November 2006

Page 17

Adjustments

Bridge Thickness - For A Service Tech Only
1. Push and hold Off till the machine stops.

2. Remove evaporator cover.

3. Remove left curtain.

4. Use a box wrench and rotate the bridge thickness

adjustment screw in 1/8 turn increments CW to

increase bridge thickness.

5. Rotate CCW to decrease bridge thickness.

Caution: Do not make the bridge too thin or the

machine will not harvest properly. Bridge thickness

adjustments are not covered by warranty.

6. Return curtain to its normal position.

7. Push and release the On button. Check next

harvest of ice. Repeat steps 1-6 if needed.

Water purge setting
The water purge is factory set to the automatic

position, suitable for most water conditions. The

setting can be changed to one of 5 manual settings or

left on automatic.

Purge

setting

1 -

Minimum

2 -

Moderate

3 - Standard 4 -

Heavy

5 -

Maximum

A - Automatic

Water

Type

RO

water or

equivalent

Factory

Setting for

typical water

High TDS

water

Any with conductivity

not less than 10

microSiemens/cm

To set:

1. Switch the machine OFF by holding the Off button

in until a number or the letter A shows on the display.

2. Press and release the On button repeatedly until

the number on the display corresponds to the desired

setting.

3. Press and release the Off switch again to return to

the normal control state.

Ice Bridge Thickness Check

Ice Thickness Sensor

Too Big

Just Right for

Small Cube

Just Right for

Medium Cube

Too

Thin

1/8 - 3/16” bridge