beautypg.com

Scotsman EH330 D with ECC Condensing Unit User Manual

Page 20

background image

EH330, EH430 D and ECC Condensing Unit

Remote Low Side Cuber User Manual

October 2014

Page 19

Cleaning, Sanitation and Maintenance

This ice system requires three types of maintenance:
• Remove the build up of mineral scale from the ice

machine’s water system and sensors.

• Sanitize the ice machine’s water system and the

ice storage bin or dispenser.

• Clean the remote air cooled condenser.

It is the User’s responsibility to keep the ice machine and ice storage bin in a sanitary condition. Without

human intervention, sanitation will not be maintained. Ice machines also require occasional cleaning of their

water systems with a specifically designed chemical. This chemical dissolves mineral build up that forms during

the ice making process.

Sanitize the ice storage bin as frequently as local health codes require, and every time the ice machine is

cleaned and sanitized.

The ice machine’s water system should be cleaned

and sanitized a minimum of twice per year.

1. Remove the front panel.

2. Remove the evaporator cover.

3. Remove all ice from the storage bin or dispenser.

4. Push and release the Clean button. The yellow

Clean light will blink and the display will show

C

. The machine will harvest any ice, drain the

reservoir and begin to refill it.

Note: Curtains must be in the closed position. Move

curtains to release any ice trapped after ice is

harvested.

5. Observe code display, when it blinks the character

A d 1” immediately go to the next step.

6. Pour 20 ounces (EH330) or 24 ounces (EH430)

of Scotsman Clear 1 ice machine scale remover

into the reservoir. The unit will circulate the scale

remover, then drain and flush it. This will take

35 minutes, then the machine will stop and the

display will show O.

Note: If unit has not been de-scaled for an extended

period of time and significant mineral scale remains,

repeat steps 4-6.

7. Mix a cleaning solution of 1 oz of ice machine

scale remover to 12 ounces of water.

8. Locate curtains, push in on edge of curtain by

pivot pin to release it. Pull curtain out of machine.

Note: EH330 curtains must go back on the same side

they were removed from.

9. Remove water distributors from ice machine.

Remove cover, inspect distributor for restricted

orifice holes, flush out any debris and open any

restricted holes. Return cover to distributor, be

sure it is fully attached.

10. Locate ice thickness sensor. Squeeze mounting

legs together to release sensor.

11. Wash the sensor and the adjustment screw with

ice machine scale remover solution, rinse with

clean water. Also wash the water distributor and

curtain with the ice machine cleaner solution.

12. Locate water level sensor. Squeeze catches

together and pull up to remove sensor.

13. Separate probes from housing and wash all

surfaces with ice machine scale remover solution.

Rinse and return probes to holder.

14. Create a solution of sanitizer by mixing a 1 gallon

or 4 liter solution of locally approved sanitizer

and clean, warm water. Use an EPA approved

food equipment sanitizer at the solution mix

recommended by the sanitizer manufacturer.

Ice machine scale remover

contains acids. Acids can

cause burns.

If concentrated cleaner comes

in contact with skin, flush with

water. If swallowed, do NOT

induce vomiting. Give large

amounts of water or milk. Call

Physician immediately. Keep

out of the reach of children.

This manual is related to the following products: