beautypg.com

Scotsman EH330 D with ECC Condensing Unit User Manual

Page 12

background image

EH330, EH430 D and ECC Condensing Unit

Remote Low Side Cuber User Manual

October 2014

Page 11

Place Ice Making Head

Remove from carton.

Remove all panels.

Utility Connection Route:

Electrical: The unit is supplied with a power cord.

There is also an interconnecting control wire that

must be routed between the ice making head and the

condensing unit.

Water Supply: The water supply can be routed from

the top or back.

Drain: The drain must be routed out the back.

Refrigeration Tubing: Field bending will allow the

tubing to be routed up or towards the back.

Adapters:

In many cases an adapter kit will be required when

placing the head unit on a bin or dispenser. See

sales information for the correct kit. Place adapter

kit onto bin or dispenser top. If adapter does NOT

have gasket tape install tape such as Scotsman part

number 19-0503-04.

Note: External drain tubing must be supported to

insure that it does not move and kink the internal

rubber tube.

Communication Cable
Plug the interconnecting communication cable into the

harness at the back of the head unit’s electrical box.

Connect Communication Cable Here

This manual is related to the following products: