Installation: Product Specifications

Location Limitations:

The product is designed to be installed indoors, in a

controlled environment. Air cooled models discharge

very warm air into the room out the back. Space must

be allowed at the sides and back for air discharge.

Water cooled models discharge warm water into the

building’s drain.

Space needs to be provided on both sides and above

for service access.

Space Limitations

Note: Although the machine will function, ice capacity

of air cooled machines will be significantly reduced

with minimal clearance at the sides, back and top.

Some space is recommended for service and

maintenance purposes on all models. 6" of space

at the sides and back are required for adequate

operation. To get the most capacity, locate the

machine away from heat producing appliances and

heating ducts, and

allow 12-18 inches of space at

the sides and top for good air flow.

Airflow is in the front, out the back. Attach a baffle kit

to the back when an air cooled unit is installed with

minimal side and top clearance. See the next page for

kit numbers.

Environmental Limitations

Minimum

Maximum

Air temperature

50

o

F.

100

o

F.

Water temperature

40

o

F.

100

o

F.

Water pressure

20 psi

80 psi

Power supply – acceptable voltage ranges

Minimum

Maximum

115 volt model

104 volts

126 volts

230 volt model

198 volts

253 volts

Warranty Information

The warranty statement for this product is provided

separately from this manual. Refer to it for applicable

coverage. In general warranty covers defects

in material or workmanship. It does not cover

maintenance, corrections to installations, or situations

when the machine is operated in circumstances that

exceed the limitations printed above.

Product Information

The product is a modular cuber. That type of machine

is designed to be placed on an ice storage bin or

an ice dispenser. Many installations only require the

matching bin, but some also require an adapter to

be placed between the bin and the cuber or between

the dispenser and the cuber. This product cannot be

stacked. See the chart for application information.

Air Flow