background image

C0322 through C1030 D Series

Air and Water Cooled User Manual

December 2014

Page 18

Ice machine cleaner contains
acids. Acids can cause burns.

If concentrated cleaner comes
in contact with skin, flush with
water. If swallowed, do NOT
induce vomiting. Give large
amounts of water or milk. Call
Physician immediately. Keep
out of the reach of children.

Cleaning, Sanitation and Maintenance

This ice system requires three types of maintenance:
• Remove the build up of mineral scale from the ice machine’s water system and sensors.
• Sanitize the ice machine’s water system and the ice storage bin or dispenser.
• Clean or replace the air filter and clean the air cooled condenser (air cooled models only).
It is the User’s responsibility to keep the ice machine and ice storage bin in a sanitary condition. Without

human intervention, sanitation will not be maintained. Ice machines also require occasional cleaning of their

water systems with a specifically designed chemical. This chemical dissolves mineral build up that forms during

the ice making process.

Sanitize the ice storage bin as frequently as local health codes require, and every time the ice machine is

cleaned and sanitized.

The ice machine’s water system should be cleaned and sanitized a minimum of twice per year.

1. Remove the front panel.

2. Remove the evaporator cover.

3. Remove all ice from the storage bin or dispenser.

4. Push and release the Clean button. The yellow

Clean light will blink and the display will show
C

. The machine will harvest any ice, drain the

reservoir and begin to refill it.

Note: Curtain(s) must be in the closed position. Move

curtain(s) to release any ice trapped after ice is

harvested.

5. Observe code display, when it blinks the

characters “A d 1” immediately go to the next step.

6. Pour 8 ounces (C0322 or C0330) or 10 ounces

(C0522, C0530 or C0630) or 12 ounces (C0830

or C1030) of Scotsman Clear 1 ice machine scale

remover into the reservoir. The unit will circulate

the scale remover, then drain and flush it. This will

take 35 minutes, then the machine will stop and

the display will show O.

Note: If unit has not been de-scaled for an extended

period of time and significant mineral scale remains,

repeat steps 4-6.

7. Mix a cleaning solution of 1 oz of ice machine

scale remover to 12 ounces of water.

8. Locate curtain, push in on edge of curtain by pivot

pin to release it. Pull curtain out of machine.

9. Remove water distributor from ice machine.

Remove cover, inspect distributor for restricted

orifice holes, flush out any debris and open any

restricted holes. Return cover to distributor, be

sure it is fully attached.

10. Locate ice thickness sensor. Squeeze mounting

legs together to release sensor.

Pull here