Plumbing Requirements

All models require connection to cold, potable water.

A hand actuated valve within site of the machine

is required. Air cooled models have a single 3/8”

FPT inlet water connection; a 3/8” FPT to 3/8” male

flare adapter is available from the local Scotsman

distributor or from a hardware store.

Water cooled models have a 1/2" FPT drain fitting

plus an additional 3/8” FPT condenser inlet water

connection.

Water Filters

If connecting to water filtration, filter only the water

to the reservoir, not to the condenser. Install a new

cartridge if the filters were used with a prior machine.

All models require drain tubing to be attached to them.

Air cooled models have a single ¾” FPT drain fitting

in the back of the cabinet. Water cooled models have

the same fitting plus an additional ½” FPT drain fitting

in the back of the cabinet.

Install new tubing when replacing a prior ice machine,

as the tubing will have been sized for the old model

and might not be correct for this one.

1. Connect water supply to water inlet fittings. 3/8" OD

tubing is recommended.

Note: This NSF listed model has a 1" anti-back flow

air break between the water inlet tube end and the

highest possible reservoir water level, no back flow

device is required for the potable water inlet.

2. Connect drain tubing to drain fittings.

3. Route the drain tubing to building drain. Follow

local codes for air gap to drain receptacle.

Drain Tubing:

Use rigid drain tubes and route them separately – do

not Tee into the bin’s drain and, if water cooled,do not

Tee the condenser drain into the reservoir or bin drain.

Vent the reservoir drain. A vertical vent at the back of

the drain, extended about 8 - 10” will allow the gravity

drain to empty and also keep any surges during

draining from discharging water out the vent.

Insulate drain tubing if in a humid environment.

Horizontal runs of drain tubing need a ¼” fall per foot

of run for proper draining.

Follow all applicable codes.

Water Fitting

Plumbing Connections

Water Cooled Shown, Air Cooled Similar

Inlet Water

Connection

Water

Supply

Water Cooled

Supply

Water

Cooled

Drain

Floor Drain

Potable

Water

Connection

Drain Vent

Reservoir

Drain

Connection

Bin Drain

Connection