Scotsman Prodigy Plus D Series User Manual
Page 13
C0322 through C1030 D Series
Air and Water Cooled User Manual
December 2014
Page 12
Electrical
The machine is not supplied with a power cord as the
machine is designed to be permanently connected.
The dataplate on the back of the cabinet details
the power requirements, including voltage, phase,
minimum circuit ampacity and maximum fuse size.
HACR type circuit breakers may be used in place of
fuses. Extension cords are not permitted. Use of a
licensed electrician is recommended.
Electrical connections are made inside the junction
box in the back panel of the ice machine.
1. Remove the junction box cover and route the
electrical supply cable through the access hole
and properly attach the power supply wires to the
leads in the junction box.
2. Install a field supplied strain relief per code. Attach
a ground wire to the ground connection in the
junction box.
3. Check voltage when complete.
4. Return the junction box cover to its original
position and secure with the original screws.
The electrical disconnect switch with fuse protection
must be a two pole type with a minimum of 3 mm
between open contacts.
Follow all applicable local, state and national codes.
Ground Wire
Connection
Install
Strain
Relief
Power
Supply
Wires
Junction
Box
Cover
Electrical Connections, Back of Unit
Cutaway View of Water Reservoir
Air Vent at Water Inlet Connection
Maximum Water Level in Reservoir
The air break is created by the gap between the
maximum water level in the reservoir (additional
water will spill out) and the water inlet connection.
Reservoir water cannot contact the water inlet
connection and in case of negative pressure, only air
can enter the water supply hose.
Air Break Description