Air and Water Cooled User Manual

December 2014

Page 12

Electrical

The machine is not supplied with a power cord as the

machine is designed to be permanently connected.

The dataplate on the back of the cabinet details

the power requirements, including voltage, phase,

minimum circuit ampacity and maximum fuse size.

HACR type circuit breakers may be used in place of

fuses. Extension cords are not permitted. Use of a

licensed electrician is recommended.

Electrical connections are made inside the junction

box in the back panel of the ice machine.

1. Remove the junction box cover and route the

electrical supply cable through the access hole

and properly attach the power supply wires to the

leads in the junction box.

2. Install a field supplied strain relief per code. Attach

a ground wire to the ground connection in the

junction box.

3. Check voltage when complete.

4. Return the junction box cover to its original

position and secure with the original screws.

The electrical disconnect switch with fuse protection

must be a two pole type with a minimum of 3 mm

between open contacts.

Follow all applicable local, state and national codes.

Ground Wire

Connection

Install

Strain

Relief

Power

Supply

Wires

Junction

Box

Cover

Electrical Connections, Back of Unit

Cutaway View of Water Reservoir

Air Vent at Water Inlet Connection

Maximum Water Level in Reservoir

The air break is created by the gap between the

maximum water level in the reservoir (additional

water will spill out) and the water inlet connection.

Reservoir water cannot contact the water inlet

connection and in case of negative pressure, only air

can enter the water supply hose.

Air Break Description