Scotsman Prodigy Plus D Series User Manual
Page 20
C0322 through C1030 D Series
Air and Water Cooled User Manual
December 2014
Page 19
11. Wash the sensor and the adjustment screw with
ice machine scale remover solution, rinse with
clean water. Also wash the water distributor and
curtain with the ice machine cleaner solution.
12. Locate water level sensor. Squeeze catches
together and pull up to remove sensor.
13. Separate probes from housing and wash all
surfaces with ice machine scale remover solution.
Rinse and return probes to holder.
14. Create a solution of sanitizer. Mix 8 ounces of
NuCalgon IMS II and 5 gallons of 105-115 degree
F. potable water to create a 200 ppm active
quaternary solution.
15. Thoroughly wash all surfaces of the ice thickness
sensor, water level sensor, curtain and water
distributor with the sanitizer solution.
16. Wash all interior surfaces of the freezing
compartment, including evaporator cover and right
side panel liner with the sanitizer solution.
17. Return water level sensor, ice thickness sensor,
water distributor and curtain to their normal
positions. Be sure water level sensor and ice
thickness sensor are completely dry.
18. Push and release the Clean button. The yellow
Clean light will blink and the display will show C.
The machine will go through a harvest cycle, drain
the reservoir and begin to refill it.
19. Observe code display, when it blinks the
characters “Ad1” immediately go to the next step.
20. Pour the sanitizing solution into the reservoir until
it is full. The unit will circulate the sanitizer, then
drain and flush it. This will take 35 minutes, then
the machine will stop and the display will show O.
21. Return all panels and covers removed to their
original positions.
22. Push and release the On button to resume ice
making.
Ice Storage Bin
1. Remove and discard all ice.
2. Mix a solution of 7 ounces of Scotsman Clear
1 ice machine scale remover in 84 ounces of
potable water and wash all interior surfaces of the
ice storage bin to remove any mineral scale build
up. Pour excess cleaner solution into the bin’s
drain.
3. Mix a solution of sanitizer and thoroughly wash
all interior surfaces of the ice storage bin. Pour
excess sanitizer solution into the bin’s drain.
Inspect Orifice Holes
Squeeze Tabs Together, Slide Out Until it Stops, Then Lift
to Remove
Inspect Water
Distributor
Release
probes by
pushing in on
white buttons
and pulling
probe down
out of holder
.