Satel ETHM-1 User Manual
Page 21

SATEL 2014-04-02
992,0, 6,'Confirmed troubles '
993,0, 6,'Confirmed use of RX key fob with low battery '
994,0, 6,'Confirmed use of ABAX key fob with low battery'
995,0, 3,'Remote RX key fob with low battery used '
995,1, 3,'Remote RX key fob with low battery used '
996,0, 3,'Remote ABAX key fob with low battery used '
996,1, 3,'Remote ABAX key fob with low battery used '
997,0, 4,'Long transmitter busy state '
997,1, 4,'Restore of long transmitter busy state '
998,0, 0,'Transmission test (station 1) '
999,0, 0,'Transmission test (station 2) '
1000,0, 1,'Trouble (zone) '
1000,1, 1,'Trouble restore (zone) '
1001,0, 2,'Forced arming '
1002,0, 4,'No network (PING test) '
1002,1, 4,'Network ok (PING test) '
1003,0, 2,'Arming aborted '
1004,0, 0,'Downloading started from ETHM/GSM module '
1005,0, 6,'ETHM-1-downloading started '
1006,0, 4,'Current battery test - absent/low voltage '
1006,1, 4,'Current battery test - ok '
1007,0, 1,'Exit time started '
1008,0, 2,'Exit time started '
1009,0,14,'SMS control - begin '
1009,1,14,'SMS control - end '
1010,0,14,'SMS with no control received '
1011,0,14,'SMS from unauthorized telephone received '
1012,0, 6,'CSD-downloading started '
1013,0, 6,'GPRS-downloading started '
1014,0, 4,'No signal on DSR input '
1014,1, 4,'Signal on DSR input ok '
1015,0, 4,'Time server error '
1015,1, 4,'Time server ok '
1016,0, 6,'Time synchronization started '
1017,0, 9,'SMS messaging ok '
1018,0, 9,'SMS messaging failed '
1019,0, 3,'Remote key fob used '
1019,1, 3,'Remote key fob used '
1020,0, 1,'LCD/PTSA/ETHM-1 initiation error '
1021,0, 1,'LCD/PTSA/ETHM-1 initiation ok '
1022,0, 0,'Downloading request from ETHM-1 module '
1023,0, 6,'Tamper info cleared '
The meaning of nnnnnnnn field:
- if users numbering:
1..240
- user
241..248
- master
249
- INT-AV
251
- SMS
252
- timer
253
- function zone
254
- Quick arm
255
- service
- if zone|expander|keypad numbering:
1..128
- zone
129..192
- expander at address 0..63
INTEGRA 24 and 32:
193..196
- real LCD keypads or INT-RS modules at address 0..3
197..200
- keypad in GuardX connected to LCD keypad at address 0..3, or www keypad
in internet browser connected to ETHM-1 at address 0..3
201
- keypad in DloadX connected to INTEGRA via RS cable
202
- keypad in DloadX connected to INTEGRA via TEL link (modem)
INTEGRA 64, 128 and 128-WRL:
193..200
- real LCD keypads or INT-RS modules at address 0..7
201..208
- keypad in GuardX connected to LCD keypad at address 0..7, or www keypad
in internet browser connected to ETHM-1 at address 0..7
209
- keypad in DloadX connected to INTEGRA via RS cable
210
- keypad in DloadX connected to INTEGRA via TEL link (modem)
- if output|expander numbering:
1..128
- output
129..192
- supply output in expander at address 0..63
Note:
in INTEGRA 256 PLUS - if event record describes zone or output (1..128), so read the uuuuu field and:
if uuuuu = 00000 - the zone or output number is 1..128,
if uuuuu = 00001 - add 128 to the zone or output number - i.e. 1..128 becomes 129..256.
- 21 -