INT-RS module returns an answer on every command - function result or 0xEF result (described below), so after sending any
command to the module please wait for answer before sending the next one (or give the module e.g. 3 seconds time-out).
0xEF result
+ 1 byte - result code:
0x00
- ok
0x01
- requesting user code not found
0x02
- no access
0x03
- selected user does not exist
0x04
- selected user already exists
0x05
- wrong code or code already exists
0x06
- telephone code already exists
0x07
- changed code is the same
0x08
- other error
0x11
- can not arm, but can use force arm
0x12
- can not arm
0x8?
- other errors
0xFF
- command accepted (i.e. data length and crc ok), will be processed