Energy Save Heat
NO
Energy Save Cool
NO
AWAY
NO
ZXT-120 functions and Parameters summaries:
FUNCTIONS
AIR
CONDITIONER
FUNCTION
Z-WAVE COMMAND CLASS
Z-WAVE
COMMAND
COMMAND
PARAMETER
COMMAND_CLASS_THERMOSTAT
_MODE
THERMOSTAT_
MODE_SET
MODE = 5
POWER ON
COMMAND_CLASS_BASIC BASIC_SET
VALUE
=
0XFF
COMMAND_CLASS_THERMOSTAT
_MODE
THERMOSTAT_
MODE_SET
MODE = 0
POWER
POWER OFF
COMMAND_CLASS_BASIC BASIC_SET
VALUE
=
0X00
AUTO
COMMAND_CLASS_THERMOSTAT
_MODE
THERMOSTAT_
MODE_SET
MODE = 3
COOL
COMMAND_CLASS_THERMOSTAT
_MODE
THERMOSTAT_
MODE_SET
MODE = 2
FAN
COMMAND_CLASS_THERMOSTAT
_MODE
THERMOSTAT_
MODE_SET
MODE = 6
HEAT
COMMAND_CLASS_THERMOSTAT
_MODE
THERMOSTAT_
MODE_SET
MODE = 1
MODE
DRY
COMMAND_CLASS_THERMOSTAT
_MODE
THERMOSTAT_
MODE_SET
MODE = 8
HEAT mode
Temperature
SETPOINT TYPE =
1, TEMPERATURE
VALUE
COOL mode
Temperature
SETPOINT TYPE =
2, TEMPERATURE
VALUE
DRY mode
Temperature
SETPOINT TYPE =
8, TEMPERATURE
VALUE
TEMPERATURE
SETTING
AUTO mode
Temperature
COMMAND_CLASS_THERMOSTAT
_SETPOINT
THERMOSTAT_
SETPOINT_SET
SETPOINT TYPE =
10, TEMPERATURE
VALUE
COMMAND_CLASS_THERMOSTAT
_FAN_MODE, v1
THERMOSTAT_
FAN_MODE_SE
T
FAN MODE = 0
FAN AUTO
COMMAND_CLASS_THERMOSTAT
_FAN_MODE, v2
THERMOSTAT_
FAN_MODE_SE
T
FAN MODE = 0, 2, or
4
COMMAND_CLASS_THERMOSTAT
_FAN_MODE, v1
THERMOSTAT_
FAN_MODE_SE
T
FAN MODE = 1
FAN LOW (1/3)
COMMAND_CLASS_THERMOSTAT
_FAN_MODE, v2
THERMOSTAT_
FAN_MODE_SE
T
FAN MODE = 1
FAN SPEED
FAN MID (2/3)
- -
-