Compressor (condenser)

Unit designed for the mechanical

conveyance and compression of

gasses. Compression serves to

significantly increase the pressure

and temperature of the medium.

Coefficient of performance

The current ratio of thermal output

produced by the heat pump to

the consumed electrical power is

referred to as the coefficient of

performance, as measured under

standardised boundary conditions

according to EN 255 / EN 14511.

A coefficient of performance of 4

means that a usable thermal output

amounting to 4-times the electrical

power consumption is available.

Single energy-source mode

The heat pump covers a large

proportion of the required thermal

output. On a few days per year an

electrical heating coil supplements

the heat pump under extremely low

outdoor temperatures.

Dimensioning of the heat pump for

air/water heat pumps is generally

based on a limit temperature (also

known as balance point) of approx.

-5 °C.

Monovalent mode

In this mode, the heat pump is

the sole heating appliance in the

building all year round. Monovalent

mode is primarily used in

combination with brine/water and

water/water heat pumps.

Storage tank

The installation of a hot-

water storage tank is generally

recommended in order to extend

the running time of the heat pump

under low heat requirements. A

storage tank is required for air/

water heat pumps in order to

bridge off-periods.

Noise

Noise is transmitted in media such

as air or water. Essentially there are

two types of noise, airborne sound

and solid-borne sound. Airborne

sound is transmitted entirely via the

air. Solid-borne sound is transmitted

in solid materials or liquids and is

only partially radiated as airborne

sound. The audible range of sound

lies between 20 and 20,000 Hz.

Sound pressure level

The sound pressure level is a

comparable characteristic quantity

for the radiated acoustic output

of a machine, for example, a heat

pump. The noise emission level

at certain distances and acoustic

environments can be measured.

The standard is based on a sound

pressure level given as a nominal

noise level.

Split AC unit

Design where one part of the

device is positioned outdoors and

the other inside the building. Both

units are connected to each other

by a refrigerant pipe.

Evaporator

Heat exchanger on a refrigerant

plant which uses the evaporation

of a working medium in order to

extract heat from its environment

at low temperatures (e.g. the

outdoor air).

Condenser

Heat exchanger on a refrigerant

plant which liquefies a working

medium in order to transmit heat

to its environment (e.g. the heating

system).

Regulations and guidelines

The erection, installation and

commissioning of heat pumps

has to be undertaken by qualified

specialist engineers. In doing so,

various standards and directives are

to be observed.

Heat requirement assessment

A precise dimensioning of the

system must be carried out for

heat pump systems in order to

maximise efficiency. Calculation of

the heat requirement is undertaken

according to national standards.

However, approximate

requirements can be determined

based on the W/m² tables

multiplied by living space to be

heated. The result of this is the

overall heat requirement, which

includes the transmission heat

requirement and the infiltration

heat loss.

Heat pump system

A heat pump system consists of

a heat pump and a heat source

system. For brine and water/water

heat pumps, the heat source system

must be made available separately.

Heat source

Medium from which the heat pump

derives heat, in other words, soil,

air and water.

Heat carrier

Liquid or gas medium (e.g. water,

brine or

air), in which heat is transported.