Remko cmf - duo, Technical data, Series cmf 320 duo – REMKO CMF 320 Duo User Manual

Page 52

background image

REMKO CMF - DUO

Series

CMF 320 Duo

Function

Heating or Cooling

Inverter technology

REMKO SuperTec

System

Split-Air/Water

Heat pump manager

Multitalent or Multitalent Plus

Storage tank for hydraulic decoupling of volumetric flows

on site

Electric booster heating / rated output

kW

optional

Water heating

optional with separate storage technology

Heating output min / max

kW

10,0 - 32,0

Heating output / compressor frequency / COP

1)

for A10/W35

kW / Hz / -

30,6 / 76 / 4,7

Heating output / compressor frequency / COP

1)

for A7/W35

kW / Hz / -

26,0 / 77 / 4,4

Heating output / compressor frequency / COP

1)

for A2/W35

kW / Hz / -

19,2 / 76 / 3,2

Heating output / compressor frequency / COP

1)

for A2/W35

kW / Hz / -

16,0 / 51 / 3,9

Heating output / compressor frequency / COP

1)

for A7/W35

kW / Hz / -

16,4 / 77 / 2,6

Heating output / compressor frequency / COP

1)

for A15/W35

kW / Hz / -

10,9 / 77 / 1,7

Heating output / compressor frequency / COP

1)

for A7/W45

kW / Hz / -

26,6 / 76 / 3,4

Heating output / compressor frequency / COP

1)

for A2/W45

kW / Hz / -

18,6 / 76 / 2,5

Heating output / compressor frequency / COP

1)

for A7/W45

kW / Hz / -

14,8 / 77 / 1,9

Heating output / compressor frequency / COP

1)

for A15/W45

kW / Hz / -

9,2 / 77 / 1,2

Heating output / compressor frequency / COP

1)

for A20/W55

kW / Hz / -

12,9 / 61 / 3,4

Heating output / compressor frequency / COP

1)

for A7/W55

kW / Hz / -

18,8 / 61 / 2,5

Heating output / compressor frequency / COP

1)

for A7/W55

kW / Hz / -

6,1 / 77 / 1,3

Cooling output / compressor frequency / EER

2)

for A35/W7

kW / Hz / -

24,2 / 74 / 3,1

Cooling output / compressor frequency / EER

2)

for A27/W7

kW / Hz / -

24,0 / 69 / 3,7

Service limits, heating

°C

-18 to +34

Service limits, cooling

°C

+15 to +46

Supply-temperature, heating water

°C

up to +60

Refrigerant / pre-charge quantity

-- / kg

R 410A

2)

/ 2 x 5,0

Refrigerant / pre-charge quantity for up to 30 m length of ordinary pipe

g/m

60

Max. permissible single refrigerant pipe length

m

each with 75

Power supply

V / Hz

400/3~N PE / 50

Starting current

A

8

Rated current consumption (for A7/W35)

A

10,6

Rated power consumption (for A7/W35)

kW

6,9

Fuse protection (outdoor unit), characteristic C

A

each with 3 x 16

Rated water flow (according to EN 14511, at ∆t 5 K)

m³/h

4,4

Pressure-loss at the condenser at rated flow

kPa

5,4

Airflow volume outdoor module

m³/h

7200

Max. operating pressure, water

bar

3,0

Hydraulic connection, supply / return

Inches

5/4“ AG

Sound-pressure level, LpA 1m (outdoor unit)

dB(A)

56/42

3)

Sound-power level in accordance with DIN EN 12102:2008-09 and ISO 9614-2

dB(A)

67,1

Dimensions, indoor unit (height/width/depth)

mm

800 / 550 / 550

Dimensions, outdoor unit (height/width/depth)

mm

1338 / 1050 / 330

Protection class outdoor unit

IP 24

Weight indoor module

kg

52

Weight outdoor module

kg

126

1) COP=coefficient of performance or performance number according to EN 14511
2) Contains greenhouse gas according to Kyoto protocol
3) Clear-field distance: 5m

Technical data