Unit commissioning

1. Turn the hygrostat

control knob an-
ticlockwise to the
“OFF” position.

2. Connect the units

to a properly fused
power socket.

3. Open the air directing flap on

the top of the unit.

4. Preselect the

required room
humidity at the
hygrostat.

The recommended approximate
settings are shown in the section
opposite.

Commissioning

Control panel

The control panel contains the
hygrostat control knob and indica-
tor lights.

Hygrostat

The desired room humidity can
be selected with the infinitely
adjustable hygrostat.

“Dehumidification“ indicator

light
This light shows that the unit is
operating correctly.

“Collector full” indicator light

This light shows that the con-
densation collector is full and
must be emptied.

“Defrost“ indicator light

This light shows that the inte-
grated automatic defrost func-
tion has started the defrost
cycle.

NOTE

At room temperatures below

10 °C

and a relative humidi-

ty below

40 %

, economical/

efficient use of the unit is not
ensured.

NOTE

Please note that the compres-
sor initially starts after a wait-
ing time of 3 minutes.

Restart protection!

ATTENTION

To avoid overheating, the units
must only be operated with
the air directing flap open.

NOTE

The units can be switched ON
and OFF via an external timer
(accessory) if required.

Prior to each commissioning or as
required, the air inlet and outlet
grilles must be checked for clog-
ging.

Important information
prior to commissioning

All electrical extension cables

must have a sufficient cross-
section and only be used fully
uncoiled.

Do not pull at the power cord.

After switching on, the units

operate fully automatically until
switched off controlled by the
hygrostat or float switch of the
full condensation collector.

The condensation collector

must be fitted correctly.

The unit will not function if the
condensation collector is not
fitted correctly!

In order to prevent compressor

damage, the units must be pro-
vided with a safeguard prevent-
ing immediate restarting of the
compressor after switching off.

The units switch on again
after a waiting time of about 3
minutes!

If the units are to operate

continuously with an external
condensation connection, the
respective chapter must be
observed.

NOTE

Clogged grilles and filters must

immediately be cleaned or
replaced.