Remko etf 320 – REMKO ETF 320 User Manual
Page 10
10
REMKO ETF 320
Adjusting the discharge
direction
The dehumidified room air is
blown out at the top of the unit.
The discharge direction can be
adjusted with the swivelling air
directing flap [S].
To open the air directing flap, press
down on the back [D].
The front opens upwards, the di-
rection of air flow can be infinitely
adjusted.
The following information must
also be observed:
■
Open the air directing flap fully
to provide an upward directed
air flow.
■
It must be ensured that the air
discharges freely.
This ensures optimal operation
of the unit!
■
It must be ensured that sensi-
It must be ensured that sensi-
tive items, e.g. indoor plants are
not placed directly in the
air flow.
D
S
Automatic defrost
The moisture contained in the
room air condenses on cooling and
covers the evaporator fins with
frost or ice depending on the air
temperature and relative humidity
(% relative humidity).
The automatic defrost function
integrated in the unit activates the
defrost cycle as required.
The frost or ice on the exchanger
surfaces can be defrosted using
hot gas as necessary.
This particularly fast and effective
defrost method guarantees a high
dehumidification capacity.
Dehumidification is interrupted
only briefly during the defrost
phase.
The “Defrost” indicator light
shows that the defrost cycle is
active.
NOTE
At a sufficiently high room
temperature, the fin surface is
not cold enough for the forma-
tion of frost so that defrosting
is unnecessary.
This makes the dehumidifier
operate highly efficiently.
Unit/humidity adjustment
The dehumidification capacity
depends solely on the room condi-
tions, room temperature, relative
humidity and observance of the
information in the chapter “Instal-
lation”.
The higher the room temperature
and relative humidity, the greater
the dehumidification capacity.
For use in living areas, a humidity
of about 45 to 60% is sufficient,
whereas in warehouses, archives,
etc., a humidity of 40 to 45%
should not be exceeded.
Adjustment of the
hygrostat for the
recommended
humidity in living
areas.
About 50 %.
Adjustment of the
hygrostat for the
recommended
humidity in archives.
About 40 %.
Adjustment of the
hygrostat for mini-
mum room humidity.
In this position, the units operate
continuously.
NOTE
The maximum possible dehu-
midification capacity is only
achieved with the air directing
flap fully open.