beautypg.com

Remko etf 320, Installation – REMKO ETF 320 User Manual

Page 8

background image

8

REMKO ETF 320

Installation

For optimal and reliable unit ope-
ration, the following information
must be observed in any event:

The units must be installed sta-

ble and horizontal to
ensure unhindered
condensation drainage.

The units should be placed in

the centre of the room where
possible to ensure optimal air
circulation.

It must be ensured that the

room air can be sucked in and
blown out freely.

A minimum distance of 50 cm

to walls must be maintained in
any event.

The units must not be installed

in the immediate vicinity of
radiators or other heat sources.

Optimal room air circulation is

achieved when the units are
installed about 1 m above the
ground.

The room to be dried or dehu-

midified must always be closed
from the ambient atmosphere.

Open windows, doors, etc., as

well as frequently entering and
leaving the room should be
avoided as far as possible.

The units must not be used in

dusty, chlorine or ammonia-
containing atmospheres.

The unit output depends solely

on the room conditions, room
temperature, relative humidity
and observance of the installa-
tion instructions.

ATTENTION

All extension cables must only
be used uncoiled.

Electrical connection

The units are

operated with
230V AC/50Hz

�lectrical connection takes place

using the fitted power cord
with safety plug.

�xtension of the connecting

cable may only take place by
qualified electricians, taking into
account the cable length, unit
installed load and local use.

NOTE

Electrical connection must take
place to supply points using a
residual-current protective unit
according to VDE 0100, part
704.
For installation of the units
in damp areas such as utility
rooms, shower rooms or simi-
lar, the units must be protected
with a residual-current-opera-
ted circuit-breaker complying
with the requirements.

Wall distance

minimum 0.5 m

Maintain distance to radiators or

other heat sources.

Keep windows and doors closed!

Diagram showing installation of the REMKO dehumidifier