Decommissioning – REMKO ETF 320 User Manual

Page 11

background image

11

Turn the hygrostat
control knob an-
ticlockwise to the

OFF“ position.

The units must be
disconnected from
the supply if they
are not going to be
used for extended
periods of time.

The condensation collector must
be emptied completely and dried
with a clean cloth.

Pay attention to subsequently
dripping condensate!

Prior to possible storage, the units
must be cleaned thoroughly and
dried.

For storage purposes, the units
should be covered with plastic
sheeting and stored in an upright
position in a protected and dry
location.

The units must only be stored
in upright in a suitable location
protected from dust and direct
sunlight.

Continuous operation with
external condensation drain

The units are provided with a

special connection on the left side.
This can be used for connecting a
standard ½” water hose.

1. To do this, remove the cover [F]

from the wall of the unit using a
suitable tool.
This is only necessary for initial
connection!

2. A suitable drainage hose of

sufficient length can now be
connected to the exposed
connection.

In unsupervised continuous op-
eration, the condensation should
preferably be discharged into drain
located at a lower level.
When using an external container
(tub, bucket, etc.), the unit must
be placed in a raised position.

Decommissioning

F

ATTENTION

It must be ensured that the
drainage hose is routed to the
drain with a gradient to allow
free discharge of the conden-
sation!

Emptying the condensation
collector

The installed condensation collec-

tor must be emptied from time to

time.

When the condensation collector

is full, dehumidification is inter-

rupted.

The “Collector full” indicator light
shows that the unit has switched
off.

1. Carefully pull out the full

collector.

2. Pour the water into a drain.

3. Carefully place the emptied

condensation collector back in
the unit.

The “Collector full” indicator light
extinguishes and the unit contin-
ues to operate fully automatically.

NOTE

The unit will only start when
the condensation collector is
fitted correctly.

NOTE

After each emptying, the con-
densation collector including
float switch must be checked
for possible damage, fouling,
etc.

ATTENTION

This unit has no overflow
protection.