beautypg.com

Initial operation of the forced – air burner – REMKO CLK 30 User Manual

Page 16

background image

16

Initial Operation of the
Forced – Air Burner


Preparation

After loosening the 4 housing bolts, remove the mount-
ing base plate of the housing so that it is suspended to
the side.
There are 6 housing bolts to disassemble for the SL 44
model (look for the arrows).
The operating parts are immediately accessible and can
now be serviced.

To service, insert or replace the nozzle, the base plate
must be suspended horizontally by hooks.

Proceed as follows:
1. Hold base plate horizontally.
2. Push right-hand mounting laterally into hook device.
3. Hook left-hand side into the lug.

Setting ignition electrode and device

D

C

B

A

All measurements are approx. values in mm. The opti-
mum setting must be adjusted to local and structural re-
quirements.

size \ dimension

A

B

C

D

SLV 11 und 33

2 - 4

4 - 6

7

2,5

SL 44

13 - 15 12 - 14

5

3

Required nozzle sizes

Selecting the required oil nozzle depends on the pump
pressure and the unit capacity.
You may only use an oil nozzle that is suitable for the
shape of the respective burner chamber with a corre-
sponding spray angle, cone properties and throughput.
You can find the required oil nozzle sizes under Techni-
cal Data.

Air slide plate

The adjustable air slide plate is used to adjust the
burner pressure to the amount of resistance in the com-
bustion chamber and the chimney draught without hav-
ing to make changes to the original cross-section.
1. Loosen socket screw.
2. Turn air slide plate to desired setting.
Pay attention to the arrows.

Turn to “min” =

reduced burner pressure

Turn to “max” =

increased burner pressure

Base plate

After changing the nozzle and setting the air slide plate,
reassemble the base plate in the reverse order.