REMKO RVT 261 DC User Manual
Page 5
The equipment is shipped in sturdy
transport packaging. Immediately
check the equipment on delivery
and make a note of any damage
or missing parts on the delivery
note. Inform the forwarding agent
and contractual partner. Warranty
claims at a later date will not be
accepted.
The RVT 261-521DC room air
conditioning units have a REMKO
RVT...AT outdoor component as
well as an indoor unit RVT...IT.
The outdoor component serves to
output the heat extracted by the
indoor unit from the room being
cooled. In heating operation, the
heat absorbed by the outdoor
component can be discharged
through the indoor unit into
the room being heated. In both
operating modes, the performance
of the compressor precisely adjusts
itself to the demand, thereby
regulating the target temperature
with minimal temperature
variations. This "inverter-
technology" saves energy as
compared to a conventional split-
system and also reduces noise
emissions to a particularly low
level.
The outdoor component can be
installed outside or in indoor areas,
providing certain requirements are
met. The indoor unit is designed
for installation high up on interior
walls. It is operated via an infrared
remote control.
The outdoor component consists
of a refrigerant circuit with
compressor, fin liquefier, liquefier
fan, reverse flow valve and flow
regulator. The outdoor component
is controlled via the regulation of
the indoor unit.
The indoor unit consists of a fin
vaporiser, vaporiser fan, regulation
system and condensation pan.
Floor consoles, wall consoles,
refrigerant pipes and condensation
pumps are available as accessories.
Description of the
equipment
Transport and
packaging
The connection between the indoor unit and the outdoor component is
made with refrigerant pipes.
Schematic of refrigerant circuit in indoor unit - cooling
Vaporiser fan
Connection to suction
pipe
Connection to injection pipe
Vaporiser
Schematic of exterior refrigerant circuit
M
M
Liquefier fan
Reverse flow valve
Liquefier
Filter dryer
Capillary tube flow regulator
Connection valve
Injection pipe
Connection valve
Suction pipe
Compressor
Connection
Manometer
Outdoor component
System layout
Stop valve
Indoor unit
Liquefier fan
Outdoor area
Injection pipe
Suction pipe
Control cable
Mains cable
Condensation pipe
Indoor area
Condensation pipe
5