The equipment is shipped in sturdy

transport packaging. Immediately

check the equipment on delivery

and make a note of any damage

or missing parts on the delivery

note. Inform the forwarding agent

and contractual partner. Warranty

claims at a later date will not be

accepted.

The RVT 261-521DC room air

conditioning units have a REMKO

RVT...AT outdoor component as

well as an indoor unit RVT...IT.
The outdoor component serves to

output the heat extracted by the

indoor unit from the room being

cooled. In heating operation, the

heat absorbed by the outdoor

component can be discharged

through the indoor unit into

the room being heated. In both

operating modes, the performance

of the compressor precisely adjusts

itself to the demand, thereby

regulating the target temperature

with minimal temperature

variations. This "inverter-

technology" saves energy as

compared to a conventional split-

system and also reduces noise

emissions to a particularly low

level.

The outdoor component can be

installed outside or in indoor areas,

providing certain requirements are

met. The indoor unit is designed

for installation high up on interior

walls. It is operated via an infrared

remote control.
The outdoor component consists

of a refrigerant circuit with

compressor, fin liquefier, liquefier

fan, reverse flow valve and flow

regulator. The outdoor component

is controlled via the regulation of

the indoor unit.
The indoor unit consists of a fin

vaporiser, vaporiser fan, regulation

system and condensation pan.
Floor consoles, wall consoles,

refrigerant pipes and condensation

pumps are available as accessories.

Description of the
equipment

Transport and
packaging

The connection between the indoor unit and the outdoor component is
made with refrigerant pipes.

Schematic of refrigerant circuit in indoor unit - cooling

Vaporiser fan

Connection to suction

pipe

Connection to injection pipe

Vaporiser

Schematic of exterior refrigerant circuit

M

M

Liquefier fan

Reverse flow valve

Liquefier

Filter dryer

Capillary tube flow regulator

Connection valve

Injection pipe

Connection valve

Suction pipe

Compressor

Connection

Manometer

Outdoor component

System layout

Stop valve

Indoor unit

Liquefier fan

Outdoor area

Injection pipe

Suction pipe

Control cable

Mains cable

Condensation pipe

Indoor area

Condensation pipe

5