Problem display by blinker code

Display Cause

Required action

E1

Communication error between outdoor component and indoor unit Contact specialist firm

E3

Liquefier fan controller faulty

Contact specialist firm

E5

Sensor vaporiser temperature faulty / short-circuited

Contact specialist firm

E6

Sensor air circulation faulty / short-circuited or

sensor vaporiser faulty / short-circuited

Contact specialist firm

H4

Operating limits of outdoor component or indoor unit exceeded

Switch system off

P0

IGBT overvoltage protection

Contact specialist firm

P1

Undervoltage protection

Switch system voltage-free and switch on again

P2

Compressor overload protection

Contact specialist firm

P4

Power board IPM shutdown system

Contact specialist firm

Installation instructions for qualified personnel

Important points prior to
installation

Transport the unit in its original
packaging as close as possible
to the installation location to
avoid transport damage.

Check the contents of the
packaging for completeness
and check the unit for visible
transport damage. Report
any damage immediately to
your contracting party and the
shipping company.

Lift the unit at the corners
and not by the refrigerant or
condensation connections.

The refrigerant pipes (injection
and suction pipe), valves and
connections must be insulated
impervious to vapour diffusion.
If necessary, also insulate the
condensation pipe.

Select an installation location
which allows air to freely
flow through the inlet and
outlet. (See section "Minimum
clearances").

Do not install the unit in
the immediate vicinity of
devices with intensive thermal
radiation. Installation near
sources of thermal radiation
reduces the output of the unit.

Open the blocking valves of the
refrigerant pipes only after the
installation is complete.

Seal off open refrigerant pipes
with suitable caps or adhesive
strips to avoid infiltration of
moisture and never kink or
compress the refrigerant pipes.

Avoid unnecessary bends. This
minimises the pressure loss
in the refrigerant pipes and
ensures that the compressor
oil can flow back without
obstruction.

Make special preparations
regarding the oil return if
the outdoor component is
located above the indoor unit.
(See section "Oil return flow
measures").

Add refrigerant if the basic
length of the refrigerant pipe
exceeds 5 metres.
The quantity of additional
refrigerant is given in chapter
"Add refrigerant".

Only use the union nuts for the
refrigerant pipes included in
the delivery, and remove them
shortly before connecting the
refrigerant pipes.

Establish all electrical
connections in accordance with
the relevant DIN- and VDE
standards.

See electrical connection
diagram always properly
insert electrical cables into the
electrical terminals. Otherwise a
fire could result.