Cleaning the condensation
pump (optional equipment)
An optional integrated or separate
condensation pump may be
included on the indoor unit, which
pumps out any accumulated
condensation into higher
positioned drains.
Observe the care and maintenance
instructions given in the separate
operating instructions manual.
Cleaning the housing
of the indoor unit
1. Disconnect the supply voltage
to the equipment.
2. Open the intake guard of the
cover and fold it upwards.
3. Clean the guard using a soft,
damp cloth.
4. Switch the supply voltage back
on.
Air filter for indoor unit
Clean the air filter at intervals of
no more than 2 weeks. Reduce this
interval in case of heavily soiled air.
Cleaning the filter
of the indoor unit
1. Disconnect the supply voltage
to the equipment.
2. Open the front side of the
device by means of folding up
the guard and allowing it to
engage (figure 1).
3. Lift the filter up slightly and pull
it out from underneath.
4. Clean the filter with
a commercially available
vacuum cleaner. In order to do
so, turn the dirty side upward
(Fig. 2)
.
5. Any dirt can be cleaned off
using lukewarm water and mild
cleaning agents. In order to do
so, turn the dirty side upward
(Fig. 3)
.
6. If water is used, let the filter
dry out properly in air before
replacing it in the unit.
7. Carefully insert the filter. Make
sure it is seated correctly.
8. Close the front side in reverse
order as described above.
9. Switch the supply voltage back
on.
10. Switch the unit back on.
2 Clean with a vacuum cleaner
3 Cleaning with lukewarm water
1 Fold up the guard
REMKO RVT...DC
14