Dehumidification MODE
It is recommended that the target temperature be set to 24°C in
dehumidifying mode. Due to the low temperature of the refrigerant, the
dew point of the air at the condenser is undercut. The excess moisture in
the air is condensed by the vaporiser, the room is dehumidified.
DEHUMIDIFICATION
MODE
MODE
HEATING Mode
In the heating mode, you can heat the room in spring or fall. The selected
room temperature is set using the
▲/▼ keys in 1 °C increments. If the
room temperature is 1 °C below the selected target temperature, the
indoor unit starts to heat the air in the room. If the set room temperature
is exceeded by approx. 1 °C, the controller will switch off the heater
function. To protect the compressor, the controller will wait 3 minutes
before switching on the heating mode again.
MODE
HEATING
OPERATION
Cooling MODE
In cooling mode, the air in the room is cooled down to the adjusted
nominal temperature. The desired room temperature is set with the
▲/▼
keys in 1 °C increments. If the room temperature is 0.5 °C above the
selected nominal temperature, then the interior unit starts to cool down
the air in the room. If the temperature falls to approx. 1 °C below the set
room temperature, the controller will switch off the cooling function. To
protect the compressor, the controller only turns cooling on again after a
waiting period of 3 minutes.
COOLING
OPERATION
MODE