REMKO RVT 263 DC User Manual
Page 9
Data specific to indoor unit
RVT 263 DC
IT
RVT 353 DC
IT
RVT 523 DC
IT
RVT 683 DC IT
Weight
kg
7
9
12
16
EDP no.
1623142
1623147
1623152
1623157
Data specific to outdoor unit
RVT 263 DC
AT
RVT 353 DC
AT
RVT 523 DC
AT
RVT 683 DC
AT
Power supply
V/Ph/
Hz
230 / 1~ / 50
Operating range, cooling
°C
+5 to +50
7)
Operating range, heating
°C
+5 to +34
7)
Air flow rate, max.
m³/h
1,800
1,800
2,200
2,700
Enclosure class
IP
24
Sound power level max.
dB (A)
59
63
61
67
Sound pressure level
5)
dB (A)
48
52
50
56
Refrigerant
6)
R 410A
Refrigerant, basic capacity
kg
1.1
1.1
1.25
2.25
Max. operating pressure
kPa
4200 / 1500
Refrigerant, addit. quantity >5m
g/m
20
40
Refrigerant piping, max. length
m
25
25
30
45
Refrigerant piping, max. height
m
10
10
15
20
Refrigerant connection
Liquid line
Inche
s
(mm)
1/4 (6.35)
1/4 (6.35)
1/4 (6.35)
3/8 (9.52)
Refrigerant connection
Suction pipe
Inche
s
(mm)
3/8 (9.52)
3/8 (9.52)
1/2 (12.70)
5/8 (15.90)
Dimensions: H/W/D
mm
590/760/285
700/845/320
Weight
kg
35
35
36
50
EDP no.
1623141
1623146
1623151
1623156
1)
Air inlet temp. TK 27°C / FK 19°C, outside temp. TK 35°C, FK 24°C, max. air flow vol., 5m pipe length
2)
Air inlet temp. TK 20°C, outside temperature TK 7°C, FK 6°C, max. air flow volume, 5m pipe length
3)
The specified value is based on results from standard testing.
The actual consumption depends on the use and location of the unit
4)
The specified value is based on the average heating period
5)
At distance of 1m in the open air; specified values are maximum values
6)
Contains greenhouse gas per the Kyoto protocol, GWP 1975 (for further information, see chapter "Adding refrigerant")
7)
This can be extended to -15°C with the appropriate accessory kit