3 connecting the outdoor unit, 4 electrical wiring diagram, Remko rvt...dc – REMKO RVT 263 DC User Manual
Page 40
8.3 Connecting the outdoor unit
Proceed as follows to connect the line:
1.
Remove the side-panel cover.
2.
Choose a cable-section according to the rele-
vant specifications.
3.
Connect the lines as shown on the electrical
connection diagram.
4.
Fix the line in the strain relief and re-
assemble the unit.
Fig. 47: Connecting the outdoor unit
8.4 Electrical wiring diagram
Connection RVT 263 DC-683 DC
230V/1~/50 Hz
L
N PE
L(1) 1 2(N) S
L(1) 1 2(N) S
B
A
1
2
Fig. 48: Electrical wiring diagram
A: Outdoor unit RVT 263 DC-683 DC AT
B: Indoor unit RVT 263 DC-683 DC IT
1: Power supply
2: Communication line
REMKO RVT...DC
40
This manual is related to the following products: