4 characteristic curves heating and cooling, Remko rvt...dc – REMKO RVT 263 DC User Manual
Page 12
2.4 Characteristic curves heating and cooling
Heating capacity RVT 263 DC
0,00
1,00
2,00
3,00
4,00
5,00
12
7
2
0
-7
-10
-15
2
1
3
A
[°C]
Fig. 4: Characteristic curves heating RVT 263 DC (specification at indoor temperature 20 °C)
A: Outdoor temperature
1: COP
2: Heating capacity in kW
3: Power consumption in kW
Outdoor temperature in °C
12
7
2
0
-7
-10
-15
Heating capacity in kW
3,33
2,93
2,79
2,65
2,36
2,22
1,91
Power consumption in kW
0,76
0,75
1,26
1,19
1,11
1,11
1,05
COP
4,37
3,91
2,21
2,23
2,12
2,00
1,82
Cooling capacity RVT 263 DC
0,00
1,00
2,00
3,00
4,00
5,00
6,00
21
25
30
35
40
45
50
2
1
3
A
[°C]
Fig. 5: Characteristic curves cooling RVT 263 DC (specification at indoor temperature 27/19 °C)
A: Outdoor temperature
1: EER
2: Cooling capacity in kW
3: Power consumption in kW
Outdoor temperature in °C
21
25
30
35
40
45
50
Cooling capacity in kW
2,80
2,99
3,01
2,90
2,49
2,36
2,30
Power consumption in kW
0,57
0,61
0,67
0,73
0,74
0,75
0,78
EER
4,93
4,87
4,51
3,97
3,36
3,13
2,94
REMKO RVT...DC
12