3 design and function, 1 unit description, 2 combinations – REMKO MXW 202 User Manual
Page 9: Design and function, Unit description, Combinations
3
Design and function
3.1
Unit description
The indoor unit on the split-design combined room
air conditioners serves to extract heat from the
indoor room being cooled. The outdoor unit then
expels this heat to the outside.
If combined heating/cooling units are operated as
heaters, the heat absorbed by the outdoor unit can
be discharged by the indoor unit into the room
being heated.
The unit is designed to be mounted high up on
indoor area. It is operated by an infra-red remote
control.
The indoor unit consists of a fin evaporator, evapo-
rator fan, controller and condensate tray. The
indoor unit can be combined with REMKO outdoor
units from the MVT 601 DC, 901 DC and 1051 DC
series that provide sufficient cooling capacity. The
outdoor unit is controlled by the controller in the
indoor unit.
Condensate pumps are available as accessories.
B
A
4
3
5
6
1
2
3
7
8
9
Fig. 2: System layout
A: Outdoor area
B: Indoor area
1: Indoor unit
2: Outdoor unit
3: Condensate drainage line
4: Condenser fan
5: Power supply
6: Shut-off valve
7: Suction pipe
8: Control line
9: Injection pipe
Refrigerant piping is used to connect the indoor
unit to the outdoor unit.
2
1
4
3
Fig. 3: Cooling cycle schematic
1: Evaporator
2: Evaporator fan
3: Suction pipe connection
4: Injection pipe connection
3.2
Combinations
Indoor units
The MXW 202-522 indoor units can be used
together with the MVT 601 DC, 901 DC and 1051
DC series outdoor units. The following combina-
tions can be selected.
Outdoor unit MVT 601 DC
Combina-
tion
MXW
202
MXW
262
MXW
352
MXW
522
One indoor unit
1
l
2
l
3
l
4
l
Two indoor units
5
ll
6
ll
7
ll
8
l
l
9
l
l
10
l
l
11
l
l
9