beautypg.com

REMKO MXW 202 User Manual

Page 17

background image

"Heating" mode

In "Heating" mode, you can heat the room in spring

or autumn. The selected room temperature is set

using the "Temp" keys in 1 °C increments. If the

room temperature is 1°C below the selected target

temperature, the indoor unit will start to heat the air

in the room. If the set room temperature is

exceeded by approx. 1°C, the controller will switch

off heating mode. To protect the compressor, the

controller will wait 3 minutes before switching on

heating mode again. The fan does not start to

operate until the temperature on the heat

exchanger is 32 °C.

Fig. 15: "Heating" mode

The heating mode has priority!

Turns on the indoor unit to the heating mode,

switch off the other indoor units from which are

in cooling mode, the cooling. During heating

operation can not be cooled.

"FAN" key

Function

1. Automatic

2. Low

3. Medium

4. High

Automatic function:

< approx. 1.5 °C = lower level

> approx. 1.5 °C = middle level

> approx. 3.5 °C = high level

4

3

2

1

FAN

FAN

FAN

FAN

Fig. 16: "Fan" key