beautypg.com

2 technical data, 1 technical data, Technical data 2.1 technical data – REMKO RKL 491 DC User Manual

Page 7: Technical data

background image

2

Technical data

2.1

Technical data

Unit data

Series

RKL 491 DC

RKL 491 DC

Operating mode

Local inverter room air conditioner in split design

Nominal cooling output

1)

kW

4.30 (1.80 to 4.60)

Energy efficiency ratio,

1)

B

Energy efficiency size SEER

1)

4.6

Power consumption, annual, Q

CE

kWh

346

Application area (room volume), approx.

120

Adjustment range indoor unit

°C/%r.H.

+16 to +30 / 35 to 80

Operating range outdoor unit

°C/%r.H.

+21 to +43 / 35 to 80

Refrigerant

R 410A

3)

Max. operating pressure

kPa

4200

Air volume flow per level, indoor unit

m³/h

380 / 520 / 600

Max. airflow volume outdoor unit

m³/h

1000

Sound pressure level p. stage, ind. unit

2)

dB(A)

45 / 48 / 54

Sound power level max., IT/AT

dB(A)

59 / 64

Power supply

V/Hz

230 / 1~/ 50

Enclosure class indoor unit / outdoor unit

IP

24 / X4

Electr. rated power consumption

1)

kW

1.31

Electr. rated current consumption

1)

A

5.60

Elec. starting current max., LRA

A

8.00

Condensate pump, flow rate, max.

mm WS

1800

Refrigerant, basic capacity

kg

1.08

Refrigerant piping, length

mm

3000, 2300 usable

Dimensions indoor unit H/W/D

mm

695 / 470 / 335

Dimensions outdoor unit H/W/D

mm

490 / 510 / 230

Weight indoor unit

kg

35.0

Weight outdoor unit

kg

14.0

Standard colour

white

silver

Serial number

1288...

1289...

EDP no.

1615490

1615491

1)

Air inlet temperature TK 27°C / FK 19°C, outside temperature TK 35 °C, FK 24 °C, max. air flow volume

2)

Distance 1m free field

3)

Contains greenhouse gas per Kyoto protocol (see also information in "Connecting line" chapter)

7