Technical data
2.1
Technical data
Unit data
Series
RKL 491 DC
RKL 491 DC
Operating mode
Local inverter room air conditioner in split design
Nominal cooling output
1)
kW
4.30 (1.80 to 4.60)
Energy efficiency ratio,
1)
B
Energy efficiency size SEER
1)
4.6
Power consumption, annual, Q
CE
kWh
346
Application area (room volume), approx.
m³
120
Adjustment range indoor unit
°C/%r.H.
+16 to +30 / 35 to 80
Operating range outdoor unit
°C/%r.H.
+21 to +43 / 35 to 80
Refrigerant
R 410A
3)
Max. operating pressure
kPa
4200
Air volume flow per level, indoor unit
m³/h
380 / 520 / 600
Max. airflow volume outdoor unit
m³/h
1000
Sound pressure level p. stage, ind. unit
2)
dB(A)
45 / 48 / 54
Sound power level max., IT/AT
dB(A)
59 / 64
Power supply
V/Hz
230 / 1~/ 50
Enclosure class indoor unit / outdoor unit
IP
24 / X4
Electr. rated power consumption
1)
kW
1.31
Electr. rated current consumption
1)
A
5.60
Elec. starting current max., LRA
A
8.00
Condensate pump, flow rate, max.
mm WS
1800
Refrigerant, basic capacity
kg
1.08
Refrigerant piping, length
mm
3000, 2300 usable
Dimensions indoor unit H/W/D
mm
695 / 470 / 335
Dimensions outdoor unit H/W/D
mm
490 / 510 / 230
Weight indoor unit
kg
35.0
Weight outdoor unit
kg
14.0
Standard colour
white
silver
Serial number
1288...
1289...
EDP no.
1615490
1615491
1)
Air inlet temperature TK 27°C / FK 19°C, outside temperature TK 35 °C, FK 24 °C, max. air flow volume
2)
Distance 1m free field
3)
Contains greenhouse gas per Kyoto protocol (see also information in "Connecting line" chapter)