6 connecting line, Connecting line, Remko rkl – REMKO RKL 491 DC User Manual
Page 14

6
Connecting line
The connecting line is connected to the indoor unit
with quick-release couplings. This provides the
facility to disconnect the connecting line from the
indoor unit for assembly purposes without losing
refrigerant.
DANGER!
The unit must be disconnected from the mains
supply during the entire process! It may only be
switched back on when all of the connections
have been made and checked. The fastenings
and all of the covers must be attached before-
hand.
DANGER!
Suitable protective gear must be worn when
connecting or disconnecting the connection
pipe.
NOTICE!
The escape of refrigerant contributes to cli-
matic change. In the event of escape, refrig-
erant with a low greenhouse potential has a
lesser impact on global warming than those
with a high greenhouse potential. This device
contains refrigerant with a greenhouse poten-
tial of 1975. That means the escape of 1 kg of
this refrigerant has an effect on global warming
that is 1975 times greater than 1 kg CO
2
,
based on 100 years. Do not conduct any work
on the refrigerant circuit or dismantle the
device - always enlist the help of qualified
experts.
Instructions for disconnecting the connecting
line:
n
Disconnect the units only immediately before
assembly and only leave the units discon-
nected for as long as is absolutely necessary.
n
Before the pipes are reconnected, it is to be
ensured that there is no dirt, moisture or other
foreign bodies in the quick release couplings
which could impair their function.
n
Always mount the cable strap as soon as the
pipelines are connected.
n
The pipelines may only be disconnected and
connected by authorised specialist engineers.
REMKO RKL