FAULT FINDING DOMESTIC HOT WATER


Before continuing it may be necessary to see Central Heating Fault Finding (Sect.8)

- All gas supply cocks are open and the gas supply has been purge of air.
- The heating system pressure is at least 1 bar min to 1.5 bar Max.
- Main Switch on and power indicator light is on
- Select “Summer” (Fig.35 item 1A)
- Domestic Hot Water control knob to maximum (Fig.35 item 5)
- Open Domestic hot tap close to the appliance


Ensure Domestic

Hot Water fl ow is
min. of 3 l/min

Check fi lters are
clean

No


Is low pressure
in the system


Re-pressure the
system


Does the fl ow
detector light?


Check/Replace
DHW diverter
valve

No

No

Yes

No

Yes

No

Yes


FAILED DHW SENSOR

- Check /Replace DHW sensor and cables


FAILED LOW WATER PRESSURE SWITCH

- Check /Replace Low water pressure switch
- Check system pressure


FAILED HEATING SENSOR

- Check / Replace heating sensor


RESET THE BOILER

- Push the Reset button on Digital Display and
check LCD if illuminate

Yes


Does the DHW
temperature
stabilise at set point ?

Yes


Check / Replace DHW potentiometer

No


END OF DOMESTIC HOT WATER TEST


Does main burner

light?

No


Check / Replace DHW sensor


FAILED FLUE TEMPERATURE

- Check operating system

No

No

No


Check and replace the
diverter valve motor

Yes