5.2 DELIVERY
5.2.1
The appliance carton containing (fi g 9):
a) boiler fully assembled
b) installation instructions and
user
instructions
c) white paper template.
Polythene bag containing
a) 2-22 mm compression ball valve complete
with 3/4” washers.
b) 1-15 mm compression ball valve complete
with 1/2” washers.
c) 1-15 mm compression ball valve.
d) 2 coach bolts and wall plugs.
e) screws and dowels
OPTIONAL EXTRAS:
Small carton containing (fi g. 11):
57 - Straight header supplied as an extra cost only when
requested
59 - Rubber seal Ø 60
66 - Flue gas sample point
FLUE EXTENSION BOX CONTAINING (fi g. 12):
1000 mm fl ue extension duct as an extra cost only when
requested for side and vertical fl ue applications
59 - Rubber seal Ø 60
63 - Air intake duct extension
64 - Flue exhaust duct extension
65 - Pipe centering spring
WARNING
Maximum allowable fl ue length 2.5 m
horizontal maximum No 2x1000 mm.
Flue duct extension used with standard fl ue.
Horizontal CSI fl ue kit
(sold separate) Fig. 10.
57 - Flue bend assembly
59 - Rubber seal Ø 60
60 - Air intake duct
61 - Flue exhaust duct
62
-
Terminal
65 - Pipe centering spring
66 - Flue gas sample point
127 - Terminal Rubber.