Ravenheat CSI PRIMARY (old model) User Manual
User’s guide, Csi primary a
ESCAPE OF GAS
Should a gas leak be suspected, contact your gas
supplier without delay.
Do NOT search for gas leaks with a naked fl ame.
WARNING: This appliance must be earthed. Do not touch
or tamper with this sealed unit or its components.
1. INTRODUCTION
1.1 Please carefully read information given in the booklet to
help you again maximum control from your appliance
with minimum trouble and cost.
1.1.1 Your Ravenheat Condensing Boiler has been
designed to supply your Central Heating reqirements.
PLEASE NOTE
Due to the high effi ciency and resulting low fl ue gas
exhaust temperature a white plume of condensation
vapour (cool steam) will be emitted from the fl ue outlet
terminal, this is quite normal. It will be particularly evident
during periods of low outdoor temparatureor when the
boiler is working at its optimum performance
1.2 CLEARANCES AROUND THE BOILER
Above 125 mm ( 5 inches)
Below 150 mm ( 6 inches)
Front 450 mm (18 inches)
Sides 5 mm (0.2 inches)
25mm (1inch) in front when installed in a cupboard
1.2.1 Minimum clearences are required for safety and
maintenance. Do NOT obstruct any purpose made
ventilation opening if boiler has been fi tted in a
compartment.
Never hang clothes,ect, over the appliance
1.3 USER CONTROLS (Fig.1)
1.3.1 This appliance is designed to operate with the
minimum of attention by the User. All the controls
are to be found on the control pannel.
1.4 OPERATING SAFETY CHECKS TO PROTECT
YOUR APPLIANCE
1.4.1 Before lighting the Appliance check that the Central
Heating system is charged with water within the
system.
If it is a pressurised system, check that the bar
gauge is not below 1.
1.4.2 A RED warning light on the control panel warns of
a fl ame failure of the burner. This can be reset
pressing on/ off switc.
1.4.3 A RED warning intermittance light on the control
panel warms of a high temperature lockout on
the overheat thermostat. This could occur due to
air or poor circulation in the boiler.
This can be reset manually by pressing on/
off switch. If lockout should persist leave the
applliance shut down and consult your installer/
service engineer immediatly.
1.4.4. The CSI Primary condensing boiler is fi tted with a
condensate outlet whitch must be connected
by the installer to a suitable discharge point
as specifi ed in the installation manual. On no
account should this discharge pipe be blocked or
modifi ed.
USER’S GUIDE
CSI PRIMARY A
CONDENSING PRIMARY INNOVATION SUPER HIGH EFFICIENTY AUTOMATIC
MODULATING BOILER FOR CENTRAL HEATING AND DOMESTIC HOT WATER
It is the law that all gas appliances are installed by
a competent person, in accordance with the gas
safety installation and use current regulations.To
the current Gas Safety (Installation and Use)
Regulations B.S.5440:2-(2000).
All CORGI registered installers carry a CORGI ID card and
have a registration number. Both should be recorded in your
boiler Log book. You can check your installer by calling
CORGI direct on 01256 732300.