Power on/off – Posiflex JIVA XT-3114 User Manual
Page 12

Part 12
POWER ON/OFF
Touch Switch
Please refer to the previous chapter PRODUCT PICTURE during this part in
order to find out the touch switch. A gentle tap on the touch switch at the lower
right side of the main unit will switch on the machine or adjust brightness
through daily operation. There must always be at least 10 seconds waiting
before switching on again once the system is powered off successfully.
Power Indicator
There is a power indicator LED module serving for several purposes under the
logo at center of lower rim of LCD panel. The
relationship between the indicator status and
other conditions is summarized in following table:
Indicator Status
System
Status
External
Power
UPS Battery
Powering Up
Off
Off
Off
Not present Not possible
Off
Off
Off
Present
Not allowed
Orange
Off
On
No influence
Allowed
Blue
On
On
No influence Not required
Blue/flash
On
Off
Activated
Not required
Orange/rapid
flash
On
Off
Running at
low capacity
Not required
Hardware Power Switch
The power switch located in the lower right part of front panel of the main unit
is a capacitor touch switch. This switch controls the power on/off of the system.
To avoid unnecessary or accidental finger rejection, essentially touching for a
longer duration on a touch control panel, at least 1 sec for ON and 3 sec for
OFF. This switch turns the system on when tapped only when external power
is present. This switch turns the system off when tapped again during power on
status. However, if the system hangs due to any reason such as software
resource conflict a simple tap on the switch may fail to turn off the power.
In this case, please utilize the forced power off feature by tapping the switch
and holding for within 10 seconds. In case the turmoil is so vigorous that some
hardware registers may be confused causing trouble for system restart or even
this forced power off, please disconnect the UPS battery if installed and the
AC power supply for few minutes. This may reset all hardware registers.
This switch can also be programmed as an ON only switch. That means, if the
application program issues a command compliant with the XT series technical